Symbiont Cell Counts Protocol

This protocol details symbiont cell counts in coral larval tissue samples. This protocol is modified from the E5 cell counts protocol.

Symbiodiniaceae Cell Density Counting Protocol

Original: 20200101
Last Revised: 20220413

Contents

  1. Materials
    • Compound light microscrope
    • Symbiont cell suspension
    • Haemocytometer (with included slides)
    • Glass pipet
    • DI Water (for cleaning)
    • Kimwipes
  2. Protocol
    • Clean haemocytometer and slide with DI water by squirting and wiping with a kimwipe. Place on microscope stand, turn on microscope, and visually inspect to make sure no cells are visible on grid.
    • Resuspend symbiont pellet (if using symbiont fraction) in a known volume of 1X PBS or filtered seawater. Record the volume used.
    • Vortex sample to homogenize. Samples are previously homogenized and separated into fractions using the separation protocol described here.
    • Use a glass pipet to mix sample by pipetting up and down, then take a small amount and load one side of haemocytometer until liquid front completely moves across the glass slide. Take a new mixed aliquot from sample and fill the other side (do not fill both sides from same aliquot)
    • Using 10x or higher objective, count cells in one side of the haemocytometer. Each grid is divided into nine large squares- keep track of how many you count. Count until you reach 100 total cells (or count all squares).
    • Note: counting should be standardized- compare your first run with someone else to ensure equivalent standards for what consitutes a cell vs. debris. For cells falling exactly on the border of two squares, cells on the left and bottom border should be considered inside of the square, while cells on the top and right border should be considered outside.
    • Repeat with other side of haemocytometer, counting the same number of squares as before.
    • Clean hemocytometer as before with DI water. Clean glass pipet with a tube of DI water.
    • Repeat above steps twice more for 6 total counts.
    • Note: Each count should count the same number of the nine large squares. For example, if the first count for sample X requires 3 squares to reach 100 squares, 3 squares should be counted on all subsequent counts for sample X.
    • Record data in datasheet.
    • Make sure average # of cells/square is consistent (calculate coefficient of variation of counts in a sample- should be less than 15%).
    • Multiply # of cells/square by 10^4 and the dilution factor to get cells/mL.
    • Multiply by homogenate volume to get total cells.
    • Normalize to surface area to get cells/surface area.
  3. References

    1. Schoepf et al., 2013. Coral Energy Reserves and Calcification in a High-CO2 World at Two Temperatures. PLoS ONE 8: e75049
    2. Weis Lab Protocol
Written on April 8, 2022